Product Description
Provides reliable 1000VA/500W power protection for your desktop computer, network workstation, audio/video components or media center. Protects against surges, line noise, blackouts and brownouts.

Supports a basic desktop PC up to 60 min. during power outage
Features 8 protected outlets—4 battery-protected, 4 surge-only
Offers automatic voltage regulation (AVR)
LCD screen reports real-time UPS and power status
Plugs into any NEMA 5-15R socket
3-year limited warranty


OVERVIEW
UPC Code    037332124999
UPS Type    Line-Interactive
INPUT
Input Phase    Single-Phase
Rated input current (Maximum Load)    12A
Nominal Input Voltage(s) Supported    120V AC
UPS Input Connection Type    5-15P; Right-Angled
UPS Input Cord Length (ft.)    6
Recommended Electrical Service    15A 120V

OUTPUT Output Capacity (VA)    1000
Output Capacity (kVA)    1
Output Capacity (Watts)    500
Output Capacity (kW)    0.5
Nominal Voltage Details    115v nominal output in battery mode
Frequency Compatibility    60 Hz
Output Voltage Regulation (Battery Mode)    +/- 5%
UPS Output Receptacles (Surge Suppression Only)    4 UPS outlets, 4 surge-only outlets
Hot-Swap PDU options    PDUB15 (2U / 8 5-15R outlets)
Output AC Waveform (AC Mode)    Sine wave
Output AC Waveform (Battery Mode)    PWM sine wave
Nominal Output Voltage(s) Supported    110V; 115V; 120V
Output Receptacles    (8) 5-15R

BATTERY
Battery Type    Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)      3 min. (500W)
Runtime Half Load (min.)      10 min. (250W)
DC System Voltage (VDC)    12
Battery Recharge Rate (Included Batteries)    Less than 16 hours from 10% to 90%
Battery Access    Battery access door
Internal UPS Replacement Battery Cartridge     RBC51
Battery Replacement Description    Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description    Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
Undervoltage Correction      Input voltages between 89 and 104 are boosted by 14%

USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display    Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing
Switches    2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness
Alarm Cancel Operation    Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm    Audible alarm indicates power-failure and low-battery status; alarm can be disabled using PowerAlert software
LED Indicators    Front panel LCD display
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating    1038
UPS AC Suppression Response Time    Instantaneous
UPS Dataline Suppression    1 line TEL/DSL (1 in / 1 out); Coax jacks (1 set)
EMI / RFI AC Noise Suppression      Yes

PHYSICAL Primary Form Factor    Tower
Installation Form Factors Supported with Included Accessories    Tower; Ultra-compact desktop
Primary UPS Depth (mm)    184
Primary UPS Height (mm)    301
Primary UPS Width (mm)    93
Shipping Dimensions (hwd / in.)    15.40 x 4.80 x 10.60
Shipping Weight (lbs.)    16.70
UPS Housing Material    ABS
UPS Power Module Dimensions (hwd, in.)    11.84 x 3.66 x 7.24
UPS Power Module Weight (kg)    7.05
UPS Power Module Weight (lbs.)    15.55
Unit Weight (lbs.)    14.9000

ENVIRONMENTAL
Operating Temperature Range    32° to 104°F (0° to 40°C)
Storage Temperature Range    5° to 122°F (-15° to 50°C)
Relative Humidity    0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)      61
Battery Mode BTU / Hr. (Full Load)      510
AC Mode Efficiency Rating (100% Load)    97%


COMMUNICATIONS PowerAlert Software    For local monitoring via the UPS’s built-in USB port, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
Communications Cable    USB cable included
WatchDog Compatibility    Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network UPS Tools (NUT) Compatibility    NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
Network Management Card Description    Network management not supported
Communications Interface    USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time      3 milliseconds
Low Voltage Transfer to Battery Power (Setpoint)    89
High Voltage Transfer to Battery Power (Setpoint)    139
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure)    Cold-start operation supported
High Availability UPS Features      Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection
Green Energy-Saving Features    Greater than 95% efficiency - GREEN UPS

APPLICATIONS UPS Applications    Home/Office Desktop; Audio/Video; High-End Desktop/Small Network; Retail/Point of Sale; Hospitality

STANDARDS & COMPLIANCE
Product Certifications    CSA (Canada); NOM (Mexico); UL 1778
Product Compliance    RoHS; FCC Part 15 Class B (USA)

WARRANTY & SUPPORT Product Warranty Period (U.S. & Canada)    3-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico)

If you can't find what you're looking for here, please contact your sales representative.        

©Bass Computers, Inc., 2025 All rights reserved.Terms of Use / Policies
10558 Bissonnet St. Houston, TX 77099 (281) 776-6700 or (800) 789-3012 
R2-Certification ORI-Certification Choice Partner Logo
Fcaebook-bass linkeding-bass
Credit-card